Titel: Pilot Study on the Use of a Laser-Structured Double Diamond Electrode (DDE) for Biofilm Removal from Dental Implant Surfaces
VerfasserIn: Koch, Maximilian
Burkovski, Andreas
Zulla, Manuel
Rosiwal, Stefan
Geißdörfer, Walter
Dittmar, Roman
Grobecker-Karl, Tanja
Sprache: Englisch
Titel: Journal of Clinical Medicine
Bandnummer: 9
Heft: 9
Verlag/Plattform: MDPI
Erscheinungsjahr: 2020
Freie Schlagwörter: boron-doped diamond
chemo-mechanical treatment
electrochemical disinfection
peri-implantitis
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: No proper treatment option for peri-implantitis exists yet. Based on previous studies showing the in vitro effectiveness of electrochemical disinfection using boron-doped diamond electrodes, novel double diamond electrodes (DDE) were tested here. Using a ceramic carrier and a laser structuring process, a clinically applicable electrode array was manufactured. Roughened metal discs (n = 24) made from Ti-Zr alloy were exposed to the oral cavities of six volunteers for 24 h in order to generate biofilm. Then, biofilm removal was carried out either using plastic curettes and chlorhexidine digluconate or electrochemical disinfection. In addition, dental implants were contaminated with ex vivo multispecies biofilm and disinfected using DDE treatment. Bacterial growth and the formation of biofilm polymer were determined as outcome measures. Chemo-mechanical treatment could not eliminate bacteria from roughened surfaces, while in most cases, a massive reduction of bacteria and biofilm polymer was observed following DDE treatment. Electrochemical disinfection was charge- and time-dependent and could also not reach complete disinfection in all instances. Implant threads had no negative effect on DDE treatment. Bacteria exhibit varying resistance to electrochemical disinfection with Bacillus subtilis, Neisseria sp., Rothia mucilaginosa, Staphylococcus haemolyticus, and Streptococcus mitis surviving 5 min of DDE application at 6 V. Electrochemical disinfection is promising but requires further optimization with respect to charge quantity and application time in order to achieve disinfection without harming host tissue.
DOI der Erstveröffentlichung: 10.3390/jcm9093036
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-323764
hdl:20.500.11880/30433
http://dx.doi.org/10.22028/D291-32376
ISSN: 2077-0383
Datum des Eintrags: 25-Jan-2021
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Zahn-, Mund- und Kieferheilkunde
Professur: M - Keiner Professur zugeordnet
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
jcm-09-03036-v2.pdf4,17 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons