Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen:
doi:10.22028/D291-32743
Titel: | Analysis of α- and β-amanitin in Human Plasma at Subnanogram per Milliliter Levels by Reversed Phase Ultra-High Performance Liquid Chromatography Coupled to Orbitrap Mass Spectrometry |
VerfasserIn: | Bambauer, Thomas P. Wagmann, Lea Weber, Armin A. Meyer, Markus R. |
Sprache: | Englisch |
Titel: | Toxins |
Bandnummer: | 12 |
Heft: | 11 |
Verlag/Plattform: | MDPI |
Erscheinungsjahr: | 2020 |
Freie Schlagwörter: | amatoxins amanitin mushroom poisoning LC-HRMS/MS bioanalysis |
DDC-Sachgruppe: | 500 Naturwissenschaften |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Amatoxins are known to be one of the main causes of serious to fatal mushroom intoxication. Thorough treatment, analytical confirmation, or exclusion of amatoxin intake is crucial in the case of any suspected mushroom poisoning. Urine is often the preferred matrix due to its higher concentrations compared to other body fluids. If urine is not available, analysis of human blood plasma is a valuable alternative for assessing the severity of intoxications. The aim of this study was to develop and validate a liquid chromatography (LC)-high resolution tandem mass spectrometry (HRMS/MS) method for confirmation and quantitation of α- and β-amanitin in human plasma at subnanogram per milliliter levels. Plasma samples of humans after suspected intake of amatoxin-containing mushrooms should be analyzed and amounts of toxins compared with already published data as well as with matched urine samples. Sample preparation consisted of protein precipitation, aqueous liquid-liquid extraction, and solid-phase extraction. Full chromatographical separation of analytes was achieved using reversed-phase chromatography. Orbitrap-based MS allowed for sufficiently sensitive identification and quantification. Validation was successfully carried out, including analytical selectivity, carry-over, matrix effects, accuracy, precision, and dilution integrity. Limits of identification were 20 pg/mL and calibration ranged from 20 pg/mL to 2000 pg/mL. The method was applied to analyze nine human plasma samples that were submitted along with urine samples tested positive for amatoxins. α-Amanitin could be identified in each plasma sample at a range from 37–2890 pg/mL, and β-amanitin was found in seven plasma samples ranging from <20–7520 pg/mL. A LC-HRMS/MS method for the quantitation of amatoxins in human blood plasma at subnanogram per milliliter levels was developed, validated, and used for the analysis of plasma samples. The method provides a valuable alternative to urine analysis, allowing thorough patient treatment but also further study the toxicokinetics of amatoxins. |
DOI der Erstveröffentlichung: | 10.3390/toxins12110671 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-327434 hdl:20.500.11880/30142 http://dx.doi.org/10.22028/D291-32743 |
ISSN: | 2072-6651 |
Datum des Eintrags: | 3-Dez-2020 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Experimentelle und Klinische Pharmakologie und Toxikologie |
Professur: | M - Prof. Dr. Markus Meyer |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
toxins-12-00671.pdf | 1,15 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons